题名: |
Concrete-Filled Steel Tube Columns Encased with Thin Precast Concrete |
其他题名: |
ACI(American Concrete Institute).(2011)."Building code requirements for structural concrete and commentary."ACI 318-11,Farmington Hills,MI. |
正文语种: |
英文 |
作者: |
Hong-Gun Park |
关键词: |
Composite column;Concrete-filled steel tube;Concrete encasement;Precast concrete;Metal and composite structures |
摘要: |
An experimental study was performed to investigate the axial-flexural load-carrying capacity of concrete-filled steel tube columns encased with thin precast concrete (PC). Six eccentrically loaded columns and one concentrically loaded column were tested. To prevent the premature failure of the concrete encasement, various reinforcement details such as studs, steel fiber, welded wire mesh, and cross ties were used. The maximum axial loads of the specimens agreed with the strengths predicted by current design codes, although in some specimens, the load-carrying capacity decreased immediately after the peak strength owing to early spalling of the concrete encasement. On the basis of the test results, the use of fiber-reinforced concrete is recommended to increase the ductility of columns by restraining the spalling of the concrete encasement. |
出版年: |
2015 |
论文唯一标识: |
P-26Y2015V141N12013 |
英文栏目名称: |
Technical Papers |
doi: |
10.1061/(ASCE)ST.1943-541X.0001303 |
期刊名称: |
Journal of Structural Engineering |
拼音刊名(出版物代码): |
P-26 |
卷: |
141 |
期: |
12 |
页码: |
126-136 |