当前位置: 首页> 国外交通期刊数据库 >详情
原文传递 Second-Order Effects on Wind-Induced Structural Behavior of High-Rise Steel Buildings
题名: Second-Order Effects on Wind-Induced Structural Behavior of High-Rise Steel Buildings
其他题名: LeMessurier,W.J.(1977)."A practical method of second order analysis.Part 2:Rigid Frames."Eng.J.,14(2),49-67.
正文语种: 英文
作者: Sejun Park
关键词: Commonwealth Advisory Aeronautical Research Council (CAARC) building;Database-assisted design (DAD); Demand-to-capacity index (DCI); Geometric stiffness approach; High-rise steel structures; Second-order effects; Wind effects
摘要: This paper investigates second-order effects on wind-induced structural dynamic behavior of a 60-story high-rise steel structure known as the Commonwealth Advisory Aeronautical Research Council (CAARC) building model. These effects are considered in the structural analysis by using a geometric stiffness method allowing the dynamic analysis to be performed without iterations. Data sets of the aerodynamic pressure on the CAARC building model for suburban exposure are used in the database-assisted design (DAD) procedure to calculate, in addition to overturning moments and shear forces at the base, members' demand-to-capacity indexes (DCIs), interstory drift ratios, and resultant accelerations. Dynamic analyses are performed using four reference mean hourly wind speeds at the rooftop for suburban terrain exposure (Uref = 20 and 40 m=s for serviceability analysis, and 60 and 80 m=s for strength analysis). The second-order effects decrease natural frequencies of vibration of the building by up to 12%. In the strength analysis with Uref = 80 m=s, second-order effects increase nondirectional peak global responses by up to 15% for overturning moments, 9% for base shears, and 10% for torsional moments. The responses of 21 members selected in this study are increased by up to 19% for columns, 41% for beams, and 31% for diagonal bracings in the case of the DCIs for the interaction of axial forces and bending moments (BPM ij ) and by up to 67% for columns, 26% for beams, and 13% for diagonal bracings in the case of the DCIs for the shear forces (BV ij). In the serviceability analysis with Uref = 40 m=s, second-order effects increase the interstory drift ratios by up to 17% and the resultant accelerations at the top floor by up to 2%. This case study shows that the second-order effects can considerably affect not only drift control but also the design of members for strength.
出版年: 2018
论文唯一标识: P-26Y2018V144N02029
英文栏目名称: TECHNICAL PAPERS
doi: 10.1061/(ASCE)ST.1943-541X.0001943
期刊名称: Journal of Structural Engineering
拼音刊名(出版物代码): P-26
卷: 144
期: 02
页码: 341-352
检索历史
应用推荐