当前位置: 首页> 国外交通期刊数据库 >详情
原文传递 Experimental and Analytical Lateral Performance of Posttensioned CLT Shear Walls and Conventional CLT Shear Walls
题名: Experimental and Analytical Lateral Performance of Posttensioned CLT Shear Walls and Conventional CLT Shear Walls
正文语种: 英文
作者: Xiaofeng Sun, S.M.ASCE; Minjuan He, M.ASCE; Zheng Li, M.ASCE
作者单位: Tongji Univ
关键词: Cross-laminated timber; Posttensioned cross-laminated timber (CLT) shear wall; Conventional cross-laminated timber shear wall; Lateral performance; Failure mode; Fiber-based nonlincar model
摘要: Cross-laminated timber (CLT) is suitable for shear walls owing to its high in-plane stiffness. However, according to a series of shaking table tests on multistory CLT structures, premature connection damage always occurs in CLT shear walls under the applied loading scenarios representing moderate and major earthquakes. To mitigate the premature corm ection damage and improve the seismic resilience of CLT shear walls, a specific kind of posttensioned (PT) CLT shear wall is proposed herein, which is constructed by posttensioning CLT wall panels to the foundation with PT steel strands or bars. Previous studies on PT CLT shear walls with vertically continuous wall panels already exist. In this study, cyclic loading tests were conducted on three PT CLT shear wall specimens with different initial posttensioning forces. Floor diaphragms were included in these wall specimens and were structurally designed to mitigate the creep defonnation of the CLT floor diaphragm subjected to perpendicular-to-grain compression. In addition, two conventional CLT shear walls with wall panels connected to the foundation using metal connections were also tested. The hysteretic behavior of the PT CLT shear walls was analyzed, and their lateral loadresisting performance was compared with that of the con vcntional CLT shear walls. Finally, fiber-based non linear finite-element models were developed within the Open System for Earthquake Engincering Simulation (OpenSees) framework to duplicate the lateral performance of PT CLT shear walls and conventional CLT shear walls. Results indicate that PT CLT shear walls exhibit excellent lateral performance with selfcentering capability. After the entire loading process, almost no damage occurred in the PT CLT shear walls compared with the premature damage occurring in the metal connections of the conventional CLT shear walls. A friction coefficient of 0.32 is recommended for the contact interface between the CLT and steel foundation. Furthermore, for the PT CLT shear walls or conventional CLT shear walls, their analytical responses from numerical models agree well with the experimental responses, indicating the potential values of these fiber-based nonlinear models for engineering design.
出版日期: 2020
出版年: 2020
期刊名称: Journal of Structural Engineering
卷: Vol.146
期: No.06
页码: 04020091