TORSIONAL STIFFNESS OF REINFORCED CONCRETE GIRDERS (PART 2) |
摘要: |
IN 1970, IN ACCORDANCE WITH THE ORIGINAL TEST PLAN, CONCLUSIVE TESTS WERE UNDERTAKEN WHICH DEALT PARTICULARLY WITH THE QUESTION OF THE SIMILARITY (2 OF 4 TESTS CARRIED OUT) AND THE ACTION OF TORSIONAL REINFORCEMENT UNDER 45 DEGREES. FOR THE OTHER 2 SIMILARITY TESTS AND THE 2 TESTS WITH T AND L CROSS SECTIONS THE TEST RIG HAD TO BE RE-BUILT. THE TEST SAMPLES WITH REINFORCEMENT ARRANGED AT 45 DEGREES OR LESS FAILED BECAUSE THE TENSILE YIELD POINT OF THE REINFORCEMENT WAS REACHED, ALTHOUGH THEY ONLY CONSISTED OF CONCRETE B 250, WHEREAS IN EARLIER COMPARATIVE BEAMS WITH ORTHOGONAL REINFORCEMENT MADE OF CONCRETE B 500 THE CONCRETE STILL FAILED. |
状态: |
Active |
资助组织: |
DEUTSCHER AUSSCHUSS FUER STAHLBETON |
项目负责人: |
LEONHARDT, F |
执行机构: |
STUTTGART UNIV. (TH) (TECHNICAL UNIVERSITY OF STUTTGART) |
开始时间: |
19630516 |
主题领域: |
Research;I24: Design of Bridges and Retaining Walls;I32: Concrete |