原文传递 Liquefaction Mitigation using Vertical Composite Drains: Full-Scale Testing for Pile Applications. Highway IDEA Program.
题名: Liquefaction Mitigation using Vertical Composite Drains: Full-Scale Testing for Pile Applications. Highway IDEA Program.
作者: rollins, k. m. strand, s. r.
关键词: site characterization, blast testing, earthquake, detonation, pore pressure, field tests, loads(forces), evaluation, modeling
摘要: This follow-on activity to a previous NCHRP-IDEA project (NCHRP-94) involved full-scale field tests to evaluate the liquefaction mitigating effect of vertical composite drains for pile applications. Work in the first phase focused on site characterization and blast testing in an untreated area. A pattern of small explosive charges was established for detonation to simulate the liquefaction process produced by an earthquake, and pilot tests were performed with various charge weights and delays to better simulate the duration and intensity of an earthquake and to determine the energy required to induce liquefaction. The field tests were performed at a site near Vancouver, British Columbia. The tests also included pile load testing before and after blast testing in areas treated and untreated with drains. The field test results were complemented with modeling analysis to determine likely pore pressure response in the area treated with drains. The test results and modeling analysis verified the effectiveness of the proposed approach. / Supplementary Notes: Sponsored by Transportation Research Board, Washington, DC. IDEA Programs. / Availability Note: Product reproduced from digital image. Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA.
总页数: u0722;126p
报告类型: 科技报告
检索历史
应用推荐