原文传递 Load Test and Load Rating Report for Bridge 305 Over Foster's Creek Located at Naval Weapons Facility, Charleston, SC.
题名: Load Test and Load Rating Report for Bridge 305 Over Foster's Creek Located at Naval Weapons Facility, Charleston, SC.
作者: schulz, j. l. commander, b. c. stanton, t. r. varela-ortiz, w. lugo, c. y.
关键词: load distribution, prestressed concrete, tanks(combat vehicles), field tests, instrumentation
摘要: This study focuses on the load rating analysis of a prestressed concrete channel-beam located at the Naval Weapons Facility in Charleston, SC, subjected to military moving loads through load testing and analytical models. The superstructure of the bridge was instrumented with 56 reusable strain transducers to accurately characterize the structure's live load response. A load test was initially performed with a 67-kip dump truck across the bridge along three lateral paths. The load test results were used to calibrate a finite element model in order to verify if the structure could safely handle larger loads imposed by the heavy equipment transporter system carrying an MIA1 Abrams tank and the Rough Terrain Container Handler DV43 handler vehicles. Once it was confirmed by the model that these larger vehicles could cross controlled load tests were performed with both vehicles, and data were recorded during multiple passes of both vehicles. These data were used to verify the predicted responses and to verify that the loads were not inducing damage to the structure. When the testing phase was completed, the data were examined thoroughly and the model was revised to best represent the actual structural responses. Load ratings were computed for the standard design and rating vehicles along with several heavy military loads. The main conclusions obtained from the load ratings are that all of the design vehicles and military vehicles can cross the bridge within the Operating (maximum) load limits. All of the vehicles, with the exception of the four-wheeled cargo handlers, can cross the bridge within the Inventory (design) load limits. Two of the most important parameters that can be determined when a load testing analysis is performed are the dynamic allowance (impact factor) and the live load distribution. / NOTE: Final rept. / Supplementary Notes: The original document contains color images. / Availability Note: Product reproduced from digital image. Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA.
总页数: u0723;87p
报告类型: 科技报告
检索历史
应用推荐