原文传递 Magnet reliability in the Fermilab Main Injector and implications for the ILC
题名: Magnet reliability in the Fermilab Main Injector and implications for the ILC
作者: /Fermilab;Tompkins, J.C.;Rahimzadeh-Kalaleh, S.;Kiemschies, O.;Harding, D.J.;Capista, D.;Blowers, J.;Tartaglia, M.A.;
关键词: Accelerators43 PARTICLE ACCELERATORS; DESIGN; FERMILAB; LINEAR COLLIDERS; MAGNETS; PERFORMANCE; RELIABILITY
摘要: The International Linear Collider reference design requires over 13000 magnets, of approximately 135 styles, which must operate with very high reliability. The Fermilab Main Injector represents a modern machine with many conventional magnet styles, each of significant quantity, that has now accumulated many hundreds of magnet-years of operation. We review here the performance of the magnets built for this machine, assess their reliability and categorize the failure modes, and discuss implications for reliability of similar magnet styles expected to be used at the ILC.
总页数: 4pages
报告类型: 科技报告