原文传递 Detection and Prevention of Carbon Monoxide Exposure in General Aviation Aircraft.
题名: Detection and Prevention of Carbon Monoxide Exposure in General Aviation Aircraft.
作者: S. H. Cheraghi; M. J. Jorgensen; R. Y. Myose;
关键词: carbon monoxide,toxic hazards,toxicity;gas mixtures, maintenance, exposure, inspection, exhaust system failure;
摘要: Exposure to carbon monoxide (CO), which is formed by the incomplete combustion of carbon-containing materials such as aviation fuels, is associated with headache, dizziness, fatigue, and at elevated doses, death. Exhaust system failures in general aviation (GA) aircraft can result in CO exposure. When this occurs in an aircraft, the end result could be an accident. This research on detection and prevention of CO exposure in GA aircraft addressed the following objectives: (1) to identify protocols to quickly alert users to the presence of excessive CO in the cabin and (2) to evaluate inspection methods and maintenance practices with respect to CO generation. These objectives were accomplished by review of (1) the National Transportation Safety Board database for CO-related incidents/accidents, (2) current CO detector technology, and (3) industry inspection and maintenance practices, Advisory Circulars, and FAA regulations with respect to GA exhaust systems. / NOTE: Final rept. / Supplementary Notes: Sponsored by Federal Aviation Administration, Washington, DC. / Availability Note: Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5301 Shawnee Road, Alexandria, VA, 22312, USA.
报告类型: 科技报告