题名: |
Shear transfer in bolted precast concrete column connections |
正文语种: |
eng |
作者: |
Jaakko Yrjoelae;Jan Bujnak |
作者单位: |
research and development organization of Peikko Group in Lahti Finland;research and development organization of Peikko Group in Kralova Slovakia |
关键词: |
Bolted connection; column design; serviceability limit state; shear |
摘要: |
Shear transfer through bolted precast concrete column connections is not a widely studied topic. The current design method is based on the standards for steel structures, and the developers adjusted it to conform with previous shear test results. The method adjusted for design in the ultimate limit states may not be suitable for assessing performance in the serviceability limit states, where the maximum shear force is limited either based on unallowed deformations or displacement. This paper assesses the suitability of the current design method for evaluating the maximum shear force in the serviceability limit states. When the authors applied the current method with load and safety factors usable in the serviceability limit states and compared the analytical results against the experimental data, they concluded that adjustments to existing design methods are needed. Improvements for design in the serviceability limit states are proposed. |
出版年: |
2024 |
期刊名称: |
PCI Journal |
卷: |
69 |
期: |
1 |
页码: |
58-72 |