原文传递 Aero-Thermal Calibration of the NASA Glenn Icing Research Tunnel (2012 Test).
题名: Aero-Thermal Calibration of the NASA Glenn Icing Research Tunnel (2012 Test).
作者: Arrington, E. A.; Pastor-barsi, C. M.; Vanzante, J. F.
关键词: Aerodynamic Heating; Data Acquisition; Heat Exchangers; Hot-wire Anemometers; Ice Formation; Mach Number; Research Facilities; Static Pressure; Steady State; Wind Tunnel Calibration; Wind Tunnels
摘要: A major modification of the refrigeration plant and heat exchanger at the NASA Glenn Icing Research Tunnel (IRT) occurred in autumn of 2011. It is standard practice at NASA Glenn to perform a full aero-thermal calibration of the test section of a wind tunnel facility upon completion of major modifications. This paper will discuss the tools and techniques used to complete an aero-thermal calibration of the IRT and the results that were acquired. The goal of this test entry was to complete a flow quality survey and aero-thermal calibration measurements in the test section of the IRT. Test hardware that was used includes the 2D Resistive Temperature Detector (RTD) array, 9-ft pressure survey rake, hot wire survey rake, and the quick check survey rake. This test hardware provides a map of the velocity, Mach number, total and static pressure, total temperature, flow angle and turbulence intensity. The data acquired were then reduced to examine pressure, temperature, velocity, flow angle, and turbulence intensity. Reduced data has been evaluated to assess how the facility meets flow quality goals. No icing conditions were tested as part of the aero-thermal calibration. However, the effects of the spray bar air injections on the flow quality and aero-thermal calibration measurements were examined as part of this calibration.
报告类型: 科技报告
检索历史
应用推荐