题名: |
Navigation and Vessel Inspection Circular No. 08-93, CH-1. Equivalent Alternatives to 46 CFR Subchapter H Requirements Related to Means of Escape, Safe Refuge Areas, and Main Vertical Zone Length. |
关键词: |
*Passenger-ships; *Evacuating-Transportation; *Fire-safety; *Inspection-.;Marine-safety; Regulations-; Guidance-; Fire-fighting; Design-criteria; Requirements-; Refuge-areas; Escape-systems; Exits-; Fire-protection; Rescues-; Merchant-vessels. |
摘要: |
The purpose of this circular is to provide equivalent alternatives to the 46 CFR Subchapter H requirements for means of escape and safe refuge areas onboard passenger vessels with a maximum enclosed width in excess of 40 meter (131 feet). 46 CFR 72.05 and 72.10 provide the design criteria for the onboard means of escape on traditional passenger vessels. However, these regulations were developed for vessel designs having a maximum enclosed width of 40 meter (131 feet). |
报告类型: |
科技报告 |