BIOMECHANICAL TOLERANCE OF THE PELVIS AND FEMUR IN LATERAL IMPACT
项目名称: BIOMECHANICAL TOLERANCE OF THE PELVIS AND FEMUR IN LATERAL IMPACT
摘要: IN A LATERAL IMPACT, THE PELVIS CAN BE HIT AT DIFFERENT LEVELS (LEVEL OF THE ILLIAC FOSSA THROUGH THE FEMUR). A DYNAMIC IMPACT TEST MACHINE WAS DEVELOPED, THE MOBILE PART OF WHICH (18 KG) IS PROPELLED BY SANDOWS. THE MOBILE MASS CAN THUS BE PROPELLED UP TO 72 KM/H. THE HEIGHT OF THE SEAT CAN BE ADJUSTED AND ENABLES THE SPECIAL DUMMY TO BE POSITIONED AS A NORMAL VEHICLE PASSENGER WOULD BE. THE COMPRESSIVE FORCE IS MEASURED WITH A SENSOR PLACED AT THE FRONT OF THE MAN. THIS MACHINE, ONCE BUILT, WILL BE INSTALLED IN THE MEDICAL FACULTY CLAUDE BERNARD. TESTS WILL BE CONDUCTED ON SPECIAL DUMMIES, AND THE HEIGHT OF THE IMPACT WILL VARY. THE SEAT ROTATES SO AS TO ALLOW IMPACT ON BOTH SIDES OF THE PELVIS. THE TESTS WILL BE CARRIED OUT AT INCREASING SPEED UNTIL FRACTURES OCCUR (ACCEPTABLE TOLERANCE LEVEL FOR A BONE SYSTEM SUCH AS THE PELVIS). X-RAYS WILL BE TAKEN AFTER EACH TEST. DISSECTION WILL TAKE PLACE AS SOON AS FRACTURES OCCUR. THE LEVEL OF OCCURRENCE OF THE FRACTURES OF THE PELVIS AND THE DIFFERENCES OBSERVED WILL BE STUDIED ON A LARGE NUMBER OF DUMMIES ACCORDING TO THE IMPACT ZONE.
状态: Active
资助组织: DIRECTION DES ROUTES ET DE LA CIRCULATION ROUTIERE (BUREAU OF PUBLIC ROADS)
项目负责人: RAMET, M;CESARI, D
执行机构: ORGANISME NATIONAL DE SECURITE ROUTIERE (NATIONAL ROAD SAFETY ORGANIZATION)
开始时间: 19790101
预计完成日期: 19801231
主题领域: Research;I84: Personal Injuries